Staple pins are the name buyers bring to the wire-to-frame connection on a damaged temporary fence panel. No part on the Australian panel pages read for this article carries that name. The infill is welded: the Econo panel page states that each horizontal wire is hand welded onto the mid-frame tube twice, and that vertical wires are welded twice at every second joint.
That changes what a rebuild means. Three spacings are published under the word pitch — apertures of 60 x 150 mm and 75 x 75 mm, infill wire at 3.0, 3.5 and 4.0 mm, and clamp hole centres at 80, 90 and 100 mm — and only one of them sizes the mesh. Name the wrong one and you rebuild the wrong part.
Key Takeaways
- No part named a staple pin appears on the Australian panel pages read for this article. The Econo page describes the infill as welded — each horizontal wire twice onto the mid-frame tube, vertical wires twice at every second joint.
- Two mesh apertures are published: 60 x 150 mm anti-climb infill on the Econo, the maxi panel and the 25NB / 40NB rows of the panels page, and 75 x 75 mm on the 2000 x 2500 mm panel, given there as the seaside wind choice.
- Wire diameter is a separate number: 3.0 mm on the Econo, 3.5 and 4.0 mm on other rows, 4.0 mm both ways on the 75 x 75 mm panel.
- Clamp hole centres — 80, 90 and 100 mm, 4.0 mm clip wall, 0.42 kg a set of two clips, one bolt and one nut — size the hardware, not the infill.
- One repair claim exists: the maxi panel page states those panels can be easily repaired if damage. No panel page lists loose infill mesh as an item.
In this guide
What Holds the Infill on an Australian Panel
The infill is a welded assembly, not a fastened one. The Econo page carries the most specific wording: each horizontal wire is hand welded onto the mid-frame tube twice, and vertical wires twice at every second joint — two passes per contact point, on a panel the same page weighs at 13 kg.
The mid-frame tube is what the welds bite into — the part worth tracking. The main panels page states that some customers ask for a middle vertical brace to reinforce the mesh panels and the frame pipe against crushing and wind, and the 3.3 m maxi panel lists mid-bracing in 32 x 2.0 mm or 25 x 2.0 mm. The 2000 x 2500 mm panel splits its frame into a 48 mm O.D. x 2.0 mm vertical tube and a 40 x 2.0 mm horizontal tube.
That geometry is why a damaged panel repays reading before you name the part. A bow across the middle puts the welds holding the horizontal wires under strain, so a loose-looking mesh may be a tube that moved rather than a wire that failed — the weld map turns that into a question you can ask. The heavy-duty page states that at 19 kg one person installs the panel with feet and clamps.
Three Numbers That Answer to Pitch
Mesh aperture is the opening size, and two are published. The Econo, the maxi panel and the 25NB and 40NB rows of the panels page carry 60 x 150 mm described as anti-climb infill; the 2000 x 2500 mm panel carries 75 x 75 mm, given on that page as its answer to seaside wind.
Wire diameter is the second number, and the Econo shows why it needs naming: that page calls Φ3.0 mm the wire diameter and lists the frame separately at Φ32 O.D. x 1.3 mm wall, although the panel is sold as the 3 mm panel. Other rows on the panels page run 3.5 mm and 4.0 mm. Clamp hole spacing is the third and belongs to the hardware: the 2000 x 2500 mm page specifies moulded clips at 4.0 mm wall in 80, 90 and 100 mm hole centres, hot dipped galvanised, 0.42 kg a set of two clips, one bolt and one nut.
The trap is that 40 mm is also a tube size. The heavy-duty line is named for its 40 mm frame tube, and that page answers a question about mesh dimensions with “40mm steel wire” — while every panel specification here gives infill wire at 3.0, 3.5 or 4.0 mm. Write the number and the thing it sizes on the same line.
When the Frame Is the Damaged Part
Rebuilding a damaged panel is a published idea without a published scope. The maxi panel page states those panels can be easily repaired if damage — the only repair claim on the Australian panel pages read for this article. No panel page lists loose infill mesh as an item, and the weld map explains why: a re-mesh is a re-weld at two passes per contact point, which is labour, not a parts swap. Fixings and bracing are covered in the site’s guides to counting fixings in a joint and rejoining panels instead of replacing them; this article stays on the mesh side.
Three scopes sit on the mesh side: re-weld released wires in the existing infill, replace the bowed mid-frame tube as part of a panel exchange, or keep the damaged panel as a donor. Whether to rejoin a joint is settled elsewhere on this site; an infill decision needs a scope before it needs a number.
| Damage you can see | Published number that sizes it | Figure on the page | Settle in writing |
|---|---|---|---|
| Cut or spread mesh wires | Aperture and infill wire | 4.0 mm wire, 60 x 150 mm (maxi) | Is a re-mesh a line item at all? |
| Seaside or high-wind run | Aperture on the tall panel | 4.0 mm wire, 75 x 75 mm | Which aperture for your exposure? |
| Bow across the middle | Mid-bracing tube | 32 x 2.0 mm or 25 x 2.0 mm | Is a braced tube supplied loose? |
| Panel out of square | Frame tube O.D. and wall | 48 mm x 2.0 mm vertical, 40 x 2.0 mm | Straighten, or write the panel off? |
| Wires released along one row | Weld cadence on the panel | Twice per wire, per the Econo page | Is re-welding priced per panel? |
Specifying a Rebuild so the Quote Matches
Put the aperture first: it is the pitch number that sizes the infill you are replacing, and the figure a replacement panel is quoted against. Then the wire diameter. Then the frame — panel height and length, tube outside diameter and wall, mid-bracing or not, and the finish designation as printed on the page you bought from, since the wording differs line by line.
Quantity is where a rebuild needs explaining. Panels carry a published minimum of 100, so twenty released welds are a labour and accessories conversation. Ask whether mixed accessory lines can travel inside a container order, and which lead time applies: the Econo page states 15-20 days for one 40′ HC after the deposit, the 2000 x 2500 mm page states 15 days for the same unit. Quote the page your panel came from.
Frequently Asked Questions
What is a staple pin on a temporary fence?
A fastener name buyers use for the wire-to-frame connection. No panel page read for this article names such a part: the Econo page states each horizontal wire is hand welded onto the mid-frame tube twice, so the infill is held by welds, not pins.
What mesh aperture do Australian temporary fence panels use?
Two are published. The Econo, maxi and 25NB / 40NB rows carry 60 x 150 mm anti-climb infill; the 2000 x 2500 mm panel carries 75 x 75 mm, given on that page as the seaside wind choice. Wire runs 3.0, 3.5 or 4.0 mm.
Can a damaged temporary fence panel be rebuilt?
The maxi panel page states those panels can be easily repaired if damage. No Australian panel page lists loose infill mesh as an item, so describe the damage — cut wire, bowed mid-tube, opened weld — and ask in writing which scope you are buying.
Why does a mesh pitch number come back wrong on a quote?
Because pitch names three things on these pages: mesh aperture, infill wire diameter, and clamp hole centres at 80, 90 or 100 mm. One heavy-duty page even answers a mesh question with its frame size. Name the part next to the number.
Conclusion
A damaged panel arrives in the wrong vocabulary. Buyers ask for staple pins; the Australian pages sell a welded infill carried on a mid-frame tube, with three numbers — aperture, wire and clamp centres — all capable of being called pitch. Naming the right one is most of the rebuild.
Write the aperture, the wire diameter, the tube outside diameter and wall, and the damage you can see, then ask which of the three scopes you are being quoted — a photograph of the damage settles the rest. The sample photographed at the top of this page carries its mesh on bolted brackets at the post, while the written specifications describe a welded infill — ask which interface your order is.