Search
Close this search box.

Panel Couplers and Clamps: Counting the Fixings in a Temporary Fencing Joint

DB Fencing’s temporary fencing pages pack and quote in sets, not in joints. The Econo sheet puts 550 sets in a 40′ HC on steel pallets and defines one set as 1 panel, 1 foot with concrete and 1 clamp with bolt and nut. That one sentence decides how your coupler clamps get counted, quoted and argued about afterwards.

Two other published lines count the same component differently. The bracing page states that a brace suits 2 x PE bases and requires 2 coupler clamps to attach to the fence panel. The Econo sheet says each stay requires 2 clamps and 2 plastic feet. Neither count lives inside the single clamp that the set carries.

Key Takeaways

  • A clamp set is four pieces: the Econo sheet weights it at 0.42 kg — 2 clips, 1 bolt and 1 nut.
  • Hole spacing is published in four steps — 75, 80, 90 or 100 mm centre to centre — on a clip moulded at 4.0 mm wall and hot-dip galvanised.
  • The clamps page names 32 mm and 40 mm pipe and then “other specs”, while a separate fencing table lists panel frames from 32 mm up to 48 mm.
  • Of the four temporary fencing pages read here, bracing is the only one carrying a spacing rule and a fixing count together: 1 brace every 3rd panel in windy, heavy-traffic or public areas, at 2 coupler clamps each.
  • Compliance is conditional on the fixings. The Econo sheet states the panel complies with AS4687-2022 when installed with feet and clamps.
  • Count in sets and in pieces. “100 clamps” reads as 400 pieces on the sheet that defines a set, and as 100 loose clips everywhere else.

What a Set Is, and What a Joint Needs

The word clamp covers one part doing three jobs. The clamps page lists them in a line: connecting temporary fencing panels, temporary fence feet and bracing. Three joints, one line item on a packing list.

That is where a fixings count slips. One clamp per panel is a carrying rule, not a joint rule, and how many sets fit a box is a separate loading calculation the site has already worked through. Three joints consume clamps — panel-to-panel, post-into-foot and brace-into-post — and the set accounts for the first, once.

The anatomy is specified more carefully than the count: two clips, one bolt, one nut, a 4.0 mm clip wall, hot-dip galvanised, 0.42 kg a set. Every line measured in sets is also a line measured in bolts, and bolts are commonly the piece that goes missing.

Close-up of a galvanised steel clamp plate bolted around two silver tubes, with scratches on the tube surface and a pale corrugated wall behind

Bore and Pitch: The Numbers That Decide Fit

Bore first. The clamps page names two sizes, 32 mm and 40 mm, and leaves the rest to “other specs steel pipes and bases”. The Econo panel is framed in 32 mm outside diameter tube at 1.3 mm wall, and the maxi and Perth sheets both state 32 x 2.0 mm, inside that range. A separate fencing specification table lists panel frames at 32, 38, 40, 42 and 48 mm.

The feet are specified across a wider ladder: concrete feet dimensions are published as generally suitable for hole sizes 32, 38, 40, 42, 48 and 50 mm. So a frame can be ordered that the foot range covers and the clamp range does not name. Three frame diameters on that table sit in the gap.

Pitch is less settled. The Econo clamp specification lists hole spacing at 75, 80, 90 or 100 mm centre to centre; the fencing table gives Fence Clamp pitch as 100 or 75 mm, two of those four. Neither says what the spacing is measured between once two frames stand side by side, or which of the four belongs to which panel.

The fix is one sentence on an enquiry: name the frame diameter and ask for the matching bore and centre-to-centre spacing, stated per joint type.

Three Joints, One Component

Panel to panel is the joint everyone pictures. The clamps page shows it, captioned as clamps connecting two temporary fence panels, and that is the full extent of what is published: no count, no spacing, no rule for a corner or a gate return.

Post into foot is the second. A clamp is listed as a connector for feet as well as panels, so the foot is fixed to the post as well as relying on its own weight. The Econo foot is a 610 x 230 x 150 mm polyethylene shell, filled in Australia or New Zealand with 30 MPa concrete and 10 mm chip to 26.5-28 kg. The photograph below shows the same joint standing on a perforated flat steel foot instead, which is what the site’s product library also carries.

A galvanised welded mesh temporary fence panel standing on a concrete surface, its post seated in a grey flat steel base plate with holes, foliage and a person's legs behind

Brace to post is the third, and the only one carrying a number. The bracing page states the brace suits 2 x PE bases and requires 2 coupler clamps to attach to the fence panel, and recommends 1 brace every 3rd panel in windy areas or in heavy traffic or public space. The Econo sheet gives the same arithmetic for a stay — 2 clamps and 2 plastic feet each — for very high winds.

Both pages say 2 and 2. Neither says whether those bases are extra feet or the panel’s own feet at that post, which moves the foot count as far as the clamp count. Where stays should sit, and what a longer sheet does to the span behind each one, is argued in the site’s guide to maxi bracing centres; this article stays on pieces.

Counting a Line Before the Order Goes In

Take 120 m of boundary and count it on published lines only: panels from the lengths on the sheets, braces from the every-third-panel rule rounded up, clamps from two per brace plus one per panel in the set.

Item on 120 m 2400 mm panels 3300 mm panels
Panels5037
Clamps inside the sets5037
Braces, every 3rd panel1713
Clamps added by bracing3426
Clamp sets to order8463
Pieces of steel at 4 per set336252
Clamp mass at 0.42 kg a set35.3 kg26.5 kg

That is arithmetic on the site’s published lines, rounded up, and it treats every brace base as an added foot because neither page says otherwise. The 2400 mm reading needs 34 sets more than the packing definition supplies.

Two galvanised pressed steel fence feet with long oval holes lying on a green workshop floor, no bolts and no branding visible

Five lines settle it before a price is struck.

  • Bore per joint type: the frame diameter you are buying, with the clamp size named against it — 32 mm, 40 mm or a stated other size, never the phrase “other specs”.
  • Centre-to-centre spacing: which of 75, 80, 90 or 100 mm, and what it is measured between on the assembled joint.
  • Unit: sets of 2 clips, 1 bolt and 1 nut, or loose clips. Write both the set count and the piece count.
  • Brace bases: whether the 2 PE bases per brace sit in addition to the feet already on the line.
  • Which standard each page is quoting: the Econo sheet cites AS4687-2022 for the installed panel and AS&NZ 4687-2007 in its own standards row, and the clamps page cites A.S. 4687-2022. Ask which feet and clamps the cited assembly used.

A drawn joint settles bore, pitch and count in one line; a clamp quantity guessed from a packing set settles none of them.

Frequently Asked Questions

How many coupler clamps go on a temporary fence joint?

No temporary fencing page here states a clamp count for a panel-to-panel joint. The published counts are 2 coupler clamps per brace and per stay, plus the single clamp that one set carries. Fix the joint count in writing before ordering.

What does 75, 80, 90 or 100 mm hole spacing refer to?

It is the centre-to-centre distance between the clamp’s bolt holes, per the Econo clamp specification. No page says which spacing suits which frame, and a separate fencing table lists only 100 or 75 mm, so ask for the number against your own panel.

Is one clamp one piece or four?

Four. The Econo sheet weights a set at 0.42 kg and defines it as 2 clips with 1 bolt and 1 nut. The stay and brace lines count clamps without stating which reading they use, so order by the set and state the piece count.

Do the clamps need the same coating as the panels?

The clamps page states hot-dip galvanising to a minimum of 42 microns, the same coating figure quoted for panels and stays on the temporary fencing lines. Ask for it on the clamp line specifically rather than assuming it follows the sheet.

Conclusion

Coupler clamps are often the smallest line on a temporary fencing enquiry and the least specified one. What is published — 0.42 kg a set, four hole spacings, two named bores, two clamps per brace, one clamp per set — describes a component, and a boundary is built from joints.

Name the bore, the spacing, the unit and the brace-base treatment in writing, and ask which assembly carries the AS 4687 claim. The company quotes within 24 hours and holds 7-day dispatch on stock items, so those answers come back before the container is booked.

Facebook
Twitter
LinkedIn
Pinterest
engineer cooperation two asian male female technician maintenance inspect relay robot system with tablet laptop control quality operate process work heavy industry 40 manufacturing factory

Talk To Our Expert

Connect with our specialists to discuss your needs and confidently start your project!

Picture of Frank Zhang

Frank Zhang

Hey, I'm Frank Zhang, the founder of DB Fencing, Family-run business, An expert of metal fence specialist.
In the past 15 years, we have helped 55 countries and 120+ Clients like construction, building, farm to protect their sites.
The purpose of this article is to share with the knowledge related to metal fence keep your home and family safe.

Categories

Recent Posts

Table Of Contents

We are at your disposal for any technical or commercial information

Table Of Contents

Picture of Frank Zhang

Frank Zhang

Hi, I’m Frank Zhang, the founder of DB Fencing, I’ve been running a factory in China that makes metal fences for 12 years now, and the purpose of this article is to share with you the knowledge related to metal fences from a Chinese supplier’s perspective.
Facebook
Twitter
LinkedIn

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email “info@metalfencetech.com”.

Your Email is necessary!!!