Search
Close this search box.

Machine Guarding Mesh Systems: Layout and Supplier Questions

Machine guarding mesh is the fixed barrier that keeps hands, arms and loose clothing out of a robot cell, a press line or a conveyor transfer. DB Fencing publishes a complete panel-and-post system for that job on its machine fencing page, and the numbers are worth reading before you sketch the layout, because they decide what a run covers and what it can keep out.

Two things stand out. The published range is modular, with seven panel widths and four heights, so layout is arithmetic rather than fabrication. And the page’s standards claims stop at weld quality, which leaves the rest of the compliance conversation to be settled in writing with the supplier.

Key Takeaways

  • The machine fencing page publishes panel heights of 1000mm, 1200mm, 1800mm and 2000mm, with widths from 200mm to 1200mm in seven steps, so a run is assembled from standard bays.
  • The mesh is 3.0mm wire at a 100 x 20mm grid inside a 20 x 20mm square-tube frame, made from low carbon steel.
  • Posts use a 60 x 60mm section in four heights from 1200mm to 2200mm, and the page’s clamps adjust in all directions.
  • The page cites EN ISO 13857 4.2.4.1 for weld quality. That standard is commonly used to set safety distances around guards, so ask which distance requirements your cell has to satisfy.
  • The page names ISO and CE certification in one line and publishes no certificate numbers. Ask for the documents before you order.
  • The factory baseline: a quote within 24 hours, a 100-panel minimum and 20-25 days for bulk production.

What the Page Publishes

The specification block on the machine fencing page lists a mesh panel height of 1000mm, 1200mm, 1800mm or 2000mm and a width chosen from 200, 300, 500, 700, 800, 1000 or 1200mm. The frame is a 20 x 20mm square tube carrying 3.0mm wire at a 100 x 20mm grid. Posts are a 60 x 60mm section at 1200mm, 1400mm, 2000mm or 2200mm tall. The page also notes that different grid sizes and colours can be customised, with yellow, black, grey or custom colours applied as an epoxy polyester powder coat.

ComponentPublished on the pageWhat it drives
Panel height1000 / 1200 / 1800 / 2000mmHow much of the hazard the mesh covers
Panel width200-1200mm in seven stepsBay length between posts
Frame tube20 x 20mmWhat the clamps grip
Wire and grid3.0mm wire at 100 x 20mmThe opening your risk assessment checks
Post section60 x 60mmClamp orientation along the line
Post height1200 / 1400 / 2000 / 2200mmFixing detail and top-of-line height

Read the ranges as a catalogue of bays rather than a single product. The page does not publish a weight for any panel, nor a load or impact rating, so nothing in a layout can lean on published strength numbers. What it does publish is geometry, and geometry is what a layout sketch needs first.

Laying Out a Run

Start the sketch from the widths. Seven published widths from 200mm to 1200mm let a line step around a column, stop short of a control cabinet or close against a conveyor transfer without cutting mesh on site. Height is the second input: the page publishes four panel heights, and which one a run uses follows from the hazard, not from the catalogue. That judgement belongs to your risk assessment, and the supplier’s job is to supply the panel that matches it.

Clamps are the connective tissue. The page describes clamps that adjust the panel in all directions, plus a modular design that assembles and disassembles quickly, which is what turns a re-layout into a bolt-off job instead of a re-fabrication. What the page does not list is any access gate or door as a separate line. Ask how people get into the guarded area, because whether that is an interlocked door, a lift-off panel or a service gap changes the bay count and the hardware list.

Stacked yellow powder-coated steel guard panels wrapped in bubble wrap with white foam edge protectors on a warehouse floor

Colours follow the same modular logic. Yellow, black and grey are the standard finishes named on the page, and a custom colour is available where the guard has to sit quietly inside an existing plant scheme. The coating itself is published as an epoxy polyester powder coat, so confirm how that finish is specified and checked when you order.

What the Standards Claims Cover

The page makes one standards claim in detail: weld quality adhering to EN ISO 13857 4.2.4.1, described as flat, strong welding marked by tiny, high-quality spots. EN ISO 13857 is the international standard commonly used to set safety distances, meaning how far a hand, arm or leg can reach towards a hazard over, around or through a guard. The page cites it for weld quality, so treat that citation as the supplier’s own reading and ask which requirements your layout has to meet.

For an Australian workshop, the broader question is which documents govern the guard. Machine-safety practice in Australia is commonly read through the AS 4024 series and the state WHS regulations, and neither the product page nor this article can settle which edition or clause applies to your cell. Put that question to your WHS adviser, and ask the supplier to state in writing which standards its guarding is built to.

The certification line is thinner still. The page names ISO and CE certification in a single sentence and publishes no certificate numbers, and it lists no load or impact rating for the mesh. If your risk assessment needs a rating, ask for one explicitly; if it needs certificates, ask for the documents themselves rather than the word certified. Our guide to weld quality inspection covers what to check on the panels when they arrive.

Questions to Put in Writing

The gaps above turn into a short list. Ask these in writing, and keep the answers with the order:

  • Grid: confirm which 100 x 20mm grid is standard, what other grid sizes are available, and which one your reach assessment needs.
  • Heights: confirm the panel and post heights you want against the four published options for each.
  • Gates: ask how access into the guarded area is handled, since the page lists no doors.
  • Fixing: ask how posts anchor to your floor. The page publishes post sections but no anchor detail.
  • Coating: ask for the powder system in writing and how it is checked before dispatch.
  • Certificates: request the ISO and CE documents, not just the words.
  • Rating: if your assessment needs a load or impact figure, ask whether one exists. None is published.
  • Infill alternatives: where a cell needs anti-cut panels rather than welded mesh, compare the expanded metal option we covered separately.

Each answer is something the factory can state plainly, and a quote that comes back within 24 hours should carry them. Where the answer is a number, put the number on the order; where it is a document, attach the document. That habit costs one email and saves a re-work at installation.

Frequently Asked Questions

What mesh grid does the machine guarding mesh use?

The page lists a 100 x 20mm grid in 3.0mm wire inside a 20 x 20mm square-tube frame, and notes that other grid sizes can be customised. Check the grid against your risk assessment’s reach requirements before ordering.

How tall can a machine guarding mesh panel go?

The published panel heights are 1000mm, 1200mm, 1800mm and 2000mm, mounted on posts from 1200mm to 2200mm. The right height depends on your hazard and reach assessment, not on the catalogue alone.

Does the page list gates or access doors?

No. The machine fencing page publishes panels and posts only, so ask the supplier how access into the guarded area is handled and what hardware it carries.

What certifications are claimed?

The page names ISO and CE certification in a single line and publishes no certificate numbers. Ask for the documents in writing before you place the order.

Conclusion

The published spec makes layout arithmetic: seven widths, four panel heights, four post heights, one grid. That arithmetic is the easy half. The other half, covering reach requirements, access, anchoring, ratings and certificates, is settled in writing, and the page gives you exactly the list of what it leaves open.

Send your bay widths, the heights you want and the questions above with the enquiry. A quote comes back within 24 hours, and the written answers are what make the guard pass handover.

Facebook
Twitter
LinkedIn
Pinterest
engineer cooperation two asian male female technician maintenance inspect relay robot system with tablet laptop control quality operate process work heavy industry 40 manufacturing factory

Talk To Our Expert

Connect with our specialists to discuss your needs and confidently start your project!

Picture of Frank Zhang

Frank Zhang

Hey, I'm Frank Zhang, the founder of DB Fencing, Family-run business, An expert of metal fence specialist.
In the past 15 years, we have helped 55 countries and 120+ Clients like construction, building, farm to protect their sites.
The purpose of this article is to share with the knowledge related to metal fence keep your home and family safe.

Categories

Recent Posts

Table Of Contents

We are at your disposal for any technical or commercial information

Table Of Contents

Picture of Frank Zhang

Frank Zhang

Hi, I’m Frank Zhang, the founder of DB Fencing, I’ve been running a factory in China that makes metal fences for 12 years now, and the purpose of this article is to share with you the knowledge related to metal fences from a Chinese supplier’s perspective.
Facebook
Twitter
LinkedIn

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email “info@metalfencetech.com”.

Your Email is necessary!!!